General Introduction of Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 
Yokogawa ZR22G zirconia oxygen detector is the probe of separate type zirconia oxygen analyzers, it works with converter ZR402G or AV550G realize oxygen concentration in combustion exhaust gas and mixed gas, measure range is 0.01 to 100vol% O2. It's applicable for standard pressure 0 to 700℃ and high temperature 700 to 1400℃.



Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector

Yokogawa's zirconia oxygen analyzers are used for combustion monitoring and control in a wide variety of applications and help industries to make considerable achievements in energy saving. The applications range from energy-consuming industries, such as iron and steel, electric power, oil and petrochemical, ceramics, pulp and paper, food, and textiles, to various combustion facilities, such as incinerators and small- and medium sized boilers. Combustion monitoring and control using the analyzer also contribute to a lowering of CO2, SOx, and NOx emissions by allowing for more complete combustion, thus preventing global warming and air pollution.

 

The ZR402G converter is equipped with an LCD touch screen which has various setting displays, a calibration display, oxygen concentration trend display, with easier operation and improvement of display functions. The converter is equipped with various standard functions such as measurement and calculation as well as maintenance functions including self-test. The ZR22G separate-type detector uses a high-reliability zirconia sensor, and its heater assembly can be replaced on site. The detector is mounted, for example, on the wall of a flue and can measure the gases directly. The ZR22S separate-type detector for explosion-proof applications is also available.

 

Features of Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector

 

· The separate type converter ZR402G incorporates a LCD touchscreen for ease of operation.

· The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs (ZR22G only).

· The probe uses a long-life, high-reliability, field replacable Zirconia sensor.

· Remote maintenance using digital communications (HART) reduces maintenance costs.

Note: HART is a registered trademark of HART Communication Foundation.

 

Specification of Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector

 

Measurement object

Oxygen concentration in combustion exhaust gas and mixed gas

Measurement system

Zirconium oxide sensor

Measurement range

0.01 to 100 vol% O2

Output signal

4 to 20 mA DC, two points (ZR402G) (maximum load resistance 550Ω)

Setting range

Any setting in the range of 0 - 5 vol%O2 to 0 - 100 vol%O2 (in 1 vol% O2), or partial range

Digital communication (HART)

250 to 550Ω, depending on number of field devices connected to the loop (multi-drop mode)

Sample gas pressure

-5 to +250 kPa (Pressure compensation option necessary over +5 kPa)

Sample gas temperature

0 to 700℃ (Probe only)
700 to 1871℃ (with 0.15m probe with JIS 5K 32 FF flange and ZR22P High Temperature Probe Adapter)

Probe length

0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0, 3.6, 4.2, 4.8, 5.4 m

Contact output

Four points (one is fail-safe, normally open)

Contact input

Two points

Calibration

Method; zero/span calibration
Calibration mode; automatic, semi-automatic and manual (with an LCD touchscreen)

Construction of detector (ZR22G)

Heater and thermocouple replaceable construction. 
Non-explosion-proof. Equivalent to NEMA4X/IP66

Construction of converter (ZR402G)

Non-explosion-proof, outdoor installation, equivalent to NEMA4X/IP66

Ambient Temperature

Probe (ZR22G): -20 to 150℃
Converter (ZR402G): -20 to 55℃)

Reference Gas System

Instrument Air (preferred): 50 kPa (200 kPa with check valve) + the pressure inside the furnace; Approx. 1 Nl/min consumption

Natural convection

Power supply

85 to 264 V AC; 45 to 66 Hz


Performance of Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector

 

Repeatability

±0.5% Maximum value of set range

Linearity

±1% Maximum value of set range

Drift

±2% Maximum value of set range/month

Response time (T90)

90% response within 5 sec (60 sec for explosion-proof ZR22S)

 


General Specification of Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector


Main Characters

Description

Sample Gas Temperature

0 to 700℃, 700 to 1400℃(0.15 m length probe and High   Temperature Probe Adapter ZO21P-H)

Sample Gas Pressure

5 to + 250kPa(compensated type recommended exceeds   5kPa)

Probe Length

0.15, 0.4, 0.7, 1.0, 1.5, 2.0, 2.5, 3.0,   3.6, 4.2, 4.8, 5.4 m

Probe Material

SUS316 (JIS)

Ambient Temperature

-20 to +150℃

Reference Gas System

Natural Convection, Instrument Air,   Pressure compensated

Instrument Air System

200kPa + the pressure inside the furnace

Wetted Material

SUS316 (JIS), Zirconia, SUS304 (JIS) or   ASTM grade 304 (flange), Hastelloy B, Inconel 600, 601)

Gas Connection:

Rc1/4 or 1/4 NPT (Female)

Wiring Connection

G1/2, Pg 13.5, M20 × 1.5, 1/2 NPT

Installation

Flange mounting

Probe Mounting Angle

Horizontal to vertically downward.

 

Model Selection of Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 

Model

Suffix Codes

Description

ZR22G

                 

Separate type Zirconia Oxygen/High Temperature Humidity   Analyzer, Detector

Length

-015

               

0.15 m (for high temperature use)

-040

               

0.4 m

-070

               

0.7 m

-100

               

1.0 m

-150

               

1.5 m

-200

               

2.0 m

-250

               

2.5 m

-300

               

3.0 m

-360

               

3.6 m

-420

               

4.2 m

-480

               

4.8 m

-540

               

5.4 m

Wetted material

 

-S

             

Stainless steel

 

-C

             

Stainless steel with Inconel calibration gas tube

Flange

   

-A

           

ANSI Class 150 2 RF

   

-B

           

ANSI Class 150 3 RF

   

-C

           

ANSI Class 150 4 RF

   

-E

           

DIN PN10 DN50 A

   

-F

           

DIN PN10 DN80 A

   

-G

           

DIN PN10 DN100 A

   

-K

           

JIS 5K 65 FF

   

-L

           

JIS 10K 65 FF

   

-M

           

JIS 10K 80 FF

   

-P

           

JIS 10K 100 FF

   

-Q

           

JIS 5K 32 FF (for high temperature use)

   

-R

           

JPI Class 150 4 RF

   

-S

           

JPI Class 150 3 RF

   

-W

           

Westinghouse

Reference gas

     

-C

         

Natural convection

     

-E

         

External connection (Instrument air)

     

-P

         

Pressure compensated

Gas Thread

       

-R

       

Rc1/4

       

-T

       

1/4NPT(Female)

Connection box thread

         

-P

     

G1/2

         

-G

     

Pg13.5

         

-M

     

M20 x1.5

         

-T

     

1/2 NPT

         

-Q

     

Quick connect

Instruction manual

           

-J

   

Japanese

           

-E

   

English

           

-C

   

Chinese

--

             

-A

 

Always -A

Options

               

/C

Inconel bolt

               

/CV

Check valve

               

/SV

Stop valve

               

/F1

Dust Filter

               

/F2

Dust Guard Protector

               

/SCT

Stainless steel tag plate

               

/PT

Printed tag plate

               

/EQ

EAC with PA

               

/ER

EAC

 

Heater Assembly of Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 

Model

Suffix Codes

Description

ZR22A

     

Heater Assembly for ZR22G

Length

-015

   

0.15 m

-040

   

0.4 m

-070

   

0.7 m

-100

   

1.0 m

-150

   

1.5 m

-200

   

2.0 m

-250

   

2.5 m

-300

   

3.0 m

Jig for change

 

-A

 

with Jig

 

-N

 

None

Reference gas

   

-A

Natural convention, External connection (Instrument   air)

   

-B

Pressure compensated (for ZR22G S2)

   

-C

Pressure compensated (for ZR22G S1)

 

High Temperature Probe Adapter for Separate Type Oxygen Analyzer   Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 

Model

Suffix Codes

Description

ZO21P

-H

         

High Temperature Probe Adapter

Material

 

-A

       

SiC

 

-B

       

SUS 310S (JIS)

Insertion length

   

-050

     

0.5m

   

-060

     

0.6m

   

-070

     

0.7m

   

-080

     

0.8m

   

-090

     

0.9m

   

-100

     

1.0m

   

-150

     

1.5m

Flange

     

-J

   

JIS 5K 50 FF

     

-N

   

JIS 10K 65 FF

     

-M

   

JIS 10K 80 FF

     

-L

   

JIS 10K 100 FF

     

-A

   

ANSI Class 150 4 RF

     

-R

   

ANSI Class 150 2 1/2 RF

     

-Q

   

ANSI Class 150 3 RF

     

-T

   

JPI Class 150 3 RF

     

-S

   

JPI Class 150 4 RF

     

-E

   

DIN PN10 DN50 A

Style code

       

*B

 

Style B

Ejector &Tag plate

         

/EJ1

Ejector Assembly with E7046EC

         

/EJ2

Ejector Assembly with E7046EN

         

/SCT

Stainless steel tag plate

 

Probe Protector for Zirconia Oxygen Analyzers   Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 

Model

Suffix Codes

Description

ZO21R

-L

     

Probe Protector (0 to 700°C)

Insertion length

 

-100

   

1.05m

 

-150

   

1.55m

 

-200

   

2.05m

Flange

   

-J

 

JIS 5K 65 FF

   

-A

 

ANSI Class 150 4 FF

Style code

     

*B

Style B

 

Standard Gas Unit    Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 

Model

Suffix Codes

Description

ZO21S

       

Standard gas unit

Power supply

 

-2

   

200 V AC 50/60 Hz

 

-3

   

220 V AC 50/60 Hz

 

-4

   

240 V AC 50/60 Hz

 

-5

   

100 V AC 50/60 Hz

 

-7

   

110 V AC 50/60 Hz

 

-8

   

115 V AC 50/60 Hz

Panel

   

-J

 

Japanese version

   

-E

 

English version

Style code

     

*A

Style A

 

Automatic Calibration Unit for ZR22G Separate Type Analyzer     Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 

Model

Suffix Codes

Description

ZR40H

       

Automatic calibration unit for ZR402G

Gas piping connection

 

-R

   

Rc1/4

 

-T

   

With 1/4 NPT (F)

Wiring connection

   

-P

 

G1/2

   

-G

 

Pg 13.5

   

-M

 

M20 x 1.5

   

-T

 

1/2 NPT

-

     

-A

Always -A



Ordering Models of  Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector
 
ZR22G-015-C-K-C-T-T-E-A ZR22G-040-C-K-C-T-T-E-A ZR22G-070-C-K-C-T-T-E-A
ZR22G-100-C-C-E-T-T-E-A ZR22G-150-C-C-E-T-T-E-A ZR22G-200-C-C-E-T-T-E-A
ZR22G-250-S-E-E-T-T-E-A ZR22G-300-S-E-E-T-T-E-A ZR22G-015-S-E-E-T-T-E-A
ZR22G-100-C-E-E-T-T-E-A ZR22G-040-C-E-E-T-T-E-A ZR22G-070-C-E-E-T-T-E-A
ZR22G-150-C-C-C-T-T-E-A ZR22G-200-C-C-C-T-T-E-A ZR22G-0250-C-C-C-T-T-E-A
ZR22G-300-S-E-C-T-T-E-A ZR22G-040-S-E-C-T-T-E-A ZR22G-070-S-E-C-T-T-E-A
ZR22G-015-C-E-C-T-T-E-A ZR22G-100-C-E-C-T-T-E-A ZR22G-150-C-E-C-T-T-E-A
ZR22G-250-S-F-C-T-T-E-A ZR22G-300-S-F-C-T-T-E-A ZR22G-070-S-F-C-T-T-E-A
ZR22G-015-C-F-C-T-T-E-A ZR22G-040-C-F-C-T-T-E-A ZR22G-100-C-F-C-T-T-E-A
ZR22G-150-S-K-C-T-T-E-A ZR22G-200-S-K-C-T-T-E-A ZR22G-250-S-K-C-T-T-E-A
ZR22G-300-S-L-C-T-T-E-A ZR22G-040-S-L-C-T-T-E-A ZR22G-070-S-L-C-T-T-E-A
ZR22G-015-C-L-C-T-T-E-A ZR22G-100-C-L-C-T-T-E-A ZR22G-150-C-L-C-T-T-E-A
ZR22G-200-S-M-C-T-T-E-A ZR22G-250-S-M-C-T-T-E-A ZR22G-300-S-M-C-T-T-E-A
ZR22G-015-C-M-C-T-T-E-A ZR22G-040-C-M-C-T-T-E-A ZR22G-070-C-M-C-T-T-E-A
ZR22G-100-S-P-C-T-T-E-A ZR22G-150-S-P-C-T-T-E-A ZR22G-200-S-P-C-T-T-E-A
ZR22G-250-C-P-C-T-T-E-A ZR22G-300-C-P-C-T-T-E-A ZR22G-040-C-P-C-T-T-E-A
ZR22G-015-S-Q-C-T-T-E-A ZR22G-100-S-Q-C-T-T-E-A ZR22G-070-S-Q-C-T-T-E-A
ZR22G-150-C-Q-C-T-T-E-A ZR22G-200-C-Q-C-T-T-E-A ZR22G-250-C-Q-C-T-T-E-A
ZR22G-300-S-R-C-T-T-E-A ZR22G-040-S-R-C-T-T-E-A ZR22G-070-S-R-C-T-T-E-A
ZR22G-015-C-R-C-T-T-E-A ZR22G-150-C-R-C-T-T-E-A ZR22G-200-C-R-C-T-T-E-A
ZR22G-250-S-S-C-T-T-E-A ZR22G-300-S-S-C-T-T-E-A ZR22G-070-S-S-C-T-T-E-A
ZR22G-015-C-S-C-T-T-E-A ZR22G-040-C-S-C-T-T-E-A ZR22G-100-C-S-C-T-T-E-A
ZR22G-150-S-W-C-T-T-E-A ZR22G-200-S-W-C-T-T-E-A ZR22G-250-S-W-C-T-T-E-A
ZR22G-300-C-W-C-T-T-E-A ZR22G-040-C-W-C-T-T-E-A ZR22G-070-C-W-C-T-T-E-A
ZR22G-015-S-G-E-T-T-E-A ZR22G-100-S-G-E-T-T-E-A ZR22G-150-S-G-E-T-T-E-A
ZR22G-200-C-G-E-T-T-E-A ZR22G-250-C-G-E-T-T-E-A ZR22G-300-C-G-E-T-T-E-A
ZR22G-015-S-A-E-T-T-E-A ZR22G-040-S-A-E-T-T-E-A ZR22G-070-S-A-E-T-T-E-A
ZR22G-100-C-A-E-T-T-E-A ZR22G-150-C-A-E-T-T-E-A ZR22G-200-C-A-E-T-T-E-A
ZR22G-250-S-B-E-T-T-E-A ZR22G-300-S-B-E-T-T-E-A ZR22G-070-S-B-E-T-T-E-A
ZR22G-015-C-B-E-T-T-E-A ZR22G-040-C-B-E-T-T-E-A ZR22G-100-C-B-E-T-T-E-A
ZR22G-150-S-C-E-T-T-E-A ZR22G-200-S-C-E-T-T-E-A ZR22G-250-S-C-E-T-T-E-A
ZR22G-300-S-F-E-T-T-E-A ZR22G-040-S-F-E-T-T-E-A ZR22G-070-S-F-E-T-T-E-A
ZR22G-015-C-F-E-T-T-E-A ZR22G-100-C-F-E-T-T-E-A ZR22G-150-C-F-E-T-T-E-A
ZR22G-200-S-K-E-T-T-E-A ZR22G-250-S-K-E-T-T-E-A ZR22G-300-S-K-E-T-T-E-A
ZR22G-015-C-K-E-T-T-E-A ZR22G-040-C-K-E-T-T-E-A ZR22G-070-C-K-E-T-T-E-A
ZR22G-150-S-L-E-T-T-E-A ZR22G-200-S-L-E-T-T-E-A ZR22G-250-S-L-E-T-T-E-A
ZR22G-300-C-L-E-T-T-E-A ZR22G-040-C-L-E-T-T-E-A ZR22G-070-C-L-E-T-T-E-A
ZR22G-015-S-M-E-T-T-E-A ZR22G-100-S-M-E-T-T-E-A ZR22G-150-S-M-E-T-T-E-A
ZR22G-200-C-M-E-T-T-E-A ZR22G-250-C-M-E-T-T-E-A ZR22G-300-C-M-E-T-T-E-A
ZR22G-040-S-P-E-T-T-E-A ZR22G-300-S-P-E-T-T-E-A ZR22G-070-S-P-E-T-T-E-A
ZR22G-070-C-P-E-T-T-E-A ZR22G-040-C-P-E-T-T-E-A ZR22G-040-C-P-E-T-T-E-A
ZR22G-100-S-Q-E-T-T-E-A ZR22G-070-S-Q-E-T-T-E-A ZR22G-015-S-Q-E-T-T-E-A
ZR22G-150-C-Q-E-T-T-E-A ZR22G-100-C-Q-E-T-T-E-A ZR22G-200-C-Q-E-T-T-E-A
ZR22G-200-S-R-E-T-T-E-A ZR22G-150-S-R-E-T-T-E-A ZR22G-300-S-R-E-T-T-E-A
ZR22G-250-C-R-E-T-T-E-A ZR22G-200-C-R-E-T-T-E-A ZR22G-100-C-R-E-T-T-E-A
ZR22G-300-C-A-C-T-T-E-A ZR22G-250-C-G-C-T-T-E-A ZR22G-070-C-G-C-T-T-E-A
ZR22G-015-C-G-C-T-T-E-A ZR22G-300-S-A-C-T-T-E-A ZR22G-040-S-A-C-T-T-E-A
ZR22G-040-S-A-C-T-T-E-A ZR22G-015-S-G-C-T-T-E-A ZR22G-100-S-G-C-T-T-E-A
ZR22G-070-S-B-C-T-T-E-A ZR22G-040-S-B-C-T-T-E-A ZR22G-200-S-B-C-T-T-E-A
ZR22G-100-C-B-C-T-T-E-A ZR22G-070-C-B-C-T-T-E-A ZR22G-300-C-B-C-T-T-E-A
ZR22G-150-S-C-C-T-T-E-A ZR22G-100-S-C-C-T-T-E-A ZR22G-070-S-C-C-T-T-E-A
ZR22G-200-S-S-E-T-T-E-A ZR22G-150-S-S-E-T-T-E-A ZR22G-040-S-S-E-T-T-E-A
ZR22G-250-C-S-E-T-T-E-A ZR22G-200-C-S-E-T-T-E-A ZR22G-100-C-S-E-T-T-E-A
ZR22G-300-S-W-E-T-T-E-A ZR22G-250-S-W-E-T-T-E-A ZR22G-150-S-W-E-T-T-E-A
ZR22G-015-C-W-E-T-T-E-A ZR22G-300-C-W-E-T-T-E-A ZR22G-250-C-W-E-T-T-E-A
ZR22G-040-S-G-P-T-T-E-A ZR22G-040-S-G-P-T-T-E-A ZR22G-070-S-G-P-T-T-E-A
ZR22G-070-C-G-P-T-T-E-A ZR22G-015-C-G-P-T-T-E-A ZR22G-040-C-G-P-T-T-E-A
ZR22G-100-S-A-P-T-T-E-A ZR22G-070-S-A-P-T-T-E-A ZR22G-040-S-A-P-T-T-E-A
ZR22G-150-C-A-P-T-T-E-A ZR22G-100-C-A-P-T-T-E-A ZR22G-070-C-A-P-T-T-E-A
ZR22G-200-S-B-P-T-T-E-A ZR22G-150-S-B-P-T-T-E-A ZR22G-150-S-B-P-T-T-E-A
ZR22G-250-C-B-P-T-T-E-A ZR22G-200-C-B-P-T-T-E-A ZR22G-200-C-B-P-T-T-E-A
ZR22G-300-S-C-P-T-T-E-A ZR22G-040-S-C-P-T-T-E-A ZR22G-300-S-C-P-T-T-E-A
ZR22G-015-C-C-P-T-T-E-A ZR22G-015-C-C-P-T-T-E-A ZR22G-070-C-C-P-T-T-E-A
ZR22G-040-S-E-P-T-T-E-A ZR22G-300-S-E-P-T-T-E-A ZR22G-040-S-E-P-T-T-E-A
ZR22G-070-C-E-P-T-T-E-A ZR22G-070-C-E-P-T-T-E-A ZR22G-015-C-E-P-T-T-E-A
ZR22G-100-S-F-P-T-T-E-A ZR22G-040-S-F-P-T-T-E-A ZR22G-070-S-F-P-T-T-E-A
ZR22G-150-C-F-P-T-T-E-A ZR22G-200-C-F-P-T-T-E-A ZR22G-100-C-F-P-T-T-E-A
ZR22G-200-S-K-P-T-T-E-A ZR22G-150-S-K-P-T-T-E-A ZR22G-150-S-K-P-T-T-E-A
ZR22G-250-C-K-P-T-T-E-A ZR22G-015-C-K-P-T-T-E-A ZR22G-250-C-K-P-T-T-E-A
ZR22G-300-S-L-P-T-T-E-A ZR22G-250-S-L-P-T-T-E-A ZR22G-300-S-L-P-T-T-E-A
ZR22G-015-C-L-P-T-T-E-A ZR22G-040-C-L-P-T-T-E-A ZR22G-250-C-L-P-T-T-E-A
ZR22G-040-C-S-P-T-T-E-A ZR22G-200-C-S-P-T-T-E-A ZR22G-200-C-S-P-T-T-E-A
ZR22G-070-S-W-P-T-T-E-A ZR22G-200-C-W-P-T-T-E-A ZR22G-300-C-W-P-T-T-E-A
ZR22G-015-S-M-P-T-T-E-A ZR22G-040-S-M-P-T-T-E-A ZR22G-200-S-M-P-T-T-E-A
ZR22G-015-C-M-P-T-T-E-A ZR22G-150-C-M-P-T-T-E-A ZR22G-100-C-M-P-T-T-E-A
ZR22G-015-S-P-P-T-T-E-A ZR22G-100-S-P-P-T-T-E-A ZR22G-150-S-P-P-T-T-E-A
ZR22G-015-C-P-P-T-T-E-A ZR22G-070-C-P-P-T-T-E-A ZR22G-200-C-P-P-T-T-E-A
ZR22G-015-S-Q-P-T-T-E-A ZR22G-015-S-Q-P-T-T-E-A ZR22G-300-S-Q-P-T-T-E-A
ZR22G-015-C-Q-P-T-T-E-A ZR22G-300-C-Q-P-T-T-E-A ZR22G-070-C-Q-P-T-T-E-A
ZR22G-015-S-R-P-T-T-E-A ZR22G-200-S-R-P-T-T-E-A ZR22G-040-S-R-P-T-T-E-A
ZR22G-015-C-R-P-T-T-E-A ZR22G-100-C-R-P-T-T-E-A ZR22G-015-C-R-P-T-T-E-A
ZR22G-015-S-S-P-T-T-E-A ZR22G-015-S-S-P-T-T-E-A ZR22G-070-S-S-P-T-T-E-A
ZR22G-015-S-G-C-T-T-E-A ZR22G-070-C-A-C-T-T-E-A ZR22G-070-C-A-C-T-T-E-A

Yokogawa ZR22G-040-S-K-C-T-M-E-A ZR22G Zirconia Oxygen Analyzer Detector

 
ZR402G-P-E-E-A,ZR402G-G-E-E-A,ZR402G-M-E-E-A,ZR402G-T-E-E-A
ZR402G-P-E-E-A/SCT,ZR402G-G-E-E-A/SCT,ZR402G-M-E-E-A/SCT,ZR402G-T-E-E-A/SCT
ZR402G-P-E-E-A/C2,ZR402G-G-E-E-A/C2,ZR402G-M-E-E-A/C2,ZR402G-T-E-E-A/C2
ZR402G-P-E-E-A/C3,ZR402G-G-E-E-A/C3,ZR402G-M-E-E-A/C3,ZR402G-T-E-E-A/C3
ZR402G-P-E-E-A/HS,ZR402G-G-E-E-A/HS,ZR402G-M-E-E-A/HS,ZR402G-T-E-E-A/HS
ZR402G-P-E-E-A/PT,ZR402G-G-E-E-A/PT,ZR402G-M-E-E-A/PT,ZR402G-T-E-E-A/PT
ZR402G-P-E-E-A/H/SCT,ZR402G-G-E-E-A/H/SCT,ZR402G-M-E-E-A/H/SCT,ZR402G-T-E-E-A/H/SCT
ZR402G-P-E-E-A/SCT/C3,ZR402G-G-E-E-A/SCT/C3,ZR402G-M-E-E-A/SCT/C3,ZR402G-T-E-E-A/SCT/C3
 

We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
 
We mainly supply YOKOGAWA,WEIDMULLER, ABB, MOELLER, SCHNEIDER ElECTIC,FUJI,OMRON,HONEYWELL,SIEMENS,FLUKE,PEPPERL+FUCHS,HIMA,Endress+ Hauser etc.
 
Why choose us?
 
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
 
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
 
3. SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
 
Packaging:
Imported with original packaging or standard export packing.Customize design is acceptable.
 
Contact:
 
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com   Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)
Previous:Yokogawa ZR402G-T-E-E-A/SCT/H ZR402G Zirconia Oxygen Analyze Next:Yokogawa AAI143-H50 AAI143-H53 AAI143-S50 AAI143-S53 Analog
 Footer begin -->